Converter Lance Systems for Copper Converting

Converter lance performance depends on oxygen control, lance gap stability and wear inspection, with Generation I and II flow ranges defining the window.

Lance Function in Converting

The converting furnace lance is the control element between the process main and the melt. It delivers oxygen-enriched air into the bath, where oxidation of sulphur and iron proceeds. Eight or fifteen branch pipes are taken from the process main, and each lance at a pipe end reaches into the furnace. The lance outlet is held at a fixed distance above the melt surface; as bath level fluctuates, a winch-driven travelling carriage corrects the height while a power head keeps the lance rotating.

Function is therefore mechanical as much as metallurgical. The lance must pass the required flow at 0.3–0.45 MPa, survive the radiant load from the converter mouth, and retract or extend without disturbing the bath. The Converting Furnace Lance System (Generation I) uses quick lance connection and remote operation; the Converting Furnace Lance System (Generation II) keeps the same pressure band and PLC control, but its flow per lance is quoted as 3500–6000 Nm³/h rather than a fixed value.

  • Delivers oxygen-enriched air to the converting furnace bath
  • Holds a fixed lance outlet distance above the melt
  • Rotates the lance while the carriage corrects height
  • Supports remote operation through PLC and DCS signals
  • Uses quick lance connection for maintenance changeover
  • Air and Oxygen Control

    Air and oxygen control starts at the process main. The Generation I system is specified for oxygen-enriched air at 21–35% O₂ and 0.3–0.45 MPa, with a flow per lance of about 5,500 Nm³/h. The Generation II system holds the same 0.3–0.45 MPa pressure band but allows 3500–6000 Nm³/h per lance. Flow meters and pressure transmitters on the main and branch pipes feed the DCS, so the operator can trend enrichment, header pressure and individual lance flow rather than trim the furnace by feel.

    The control objective is not a fixed setpoint but a stable mass flow per lance at the required enrichment. If a lance drifts, the DCS comparison between branch flows exposes it. Keep the pressure band inside 0.3–0.45 MPa; lower pressure weakens penetration, while higher pressure raises splashing and refractory load. Use PLC control for carriage motion, lance rotation and interlocks, and keep flow and pressure transmitters calibrated so the quoted flow ranges remain meaningful in service.

    Branch count matters because the control strategy is per lance, not only per header. With eight or fifteen branch pipes, a header pressure transmitter alone cannot reveal a partly blocked lance; each branch needs its own flow indication or a repeatable pressure-drop check. Set the PLC alarm band from the commissioned flow at the normal pressure band, and review it after every nozzle change. This keeps the quoted 3500–6000 Nm³/h range for the Generation II system, or the ~5,500 Nm³/h Generation I figure, tied to actual branch behaviour.

    ParameterGeneration IGeneration II
    Pressure band0.3–0.45 MPa0.3–0.45 MPa
    Flow per lance~5,500 Nm³/h3500–6000 Nm³/h
    Lance travel~3 m/min3 m/min
    Rotation speed≤10 r/min~8 rpm
    Control modePLCPLC

    Cooling and Wear Management

    Cooling and wear are linked because both are driven by the lance tip environment. The tip sees radiant heat from the bath, splash from oxygen jets and thermal cycling during retraction. A cooling circuit should be sized per lance geometry and plant water quality; the specification does not fix a universal coolant flow, so treat any proposed value as a design output, not a catalogue constant. Monitor return temperature, pressure drop and flow per lance, and alarm on drift before the tip overheats.

    Wear appears first at the nozzle bore and the outer lance tube. Oxidation, slag adhesion and thermal shock change the effective outlet area, which shows up as a flow deviation at constant pressure. Inspect the nozzle bore, lance straightness and wall thickness at each lance change; record the results against the branch position. The Generation I and Generation II systems both use PLC control, so trend data can be aligned with maintenance records without adding a separate historian.

  • Inspect nozzle bore after each lance change
  • Check lance straightness against the carriage guides
  • Record wall thickness by branch position
  • Compare flow deviation at constant pressure
  • Verify coolant return temperature and pressure drop
  • Positioning Accuracy at the Bath

    Positioning accuracy is the practical expression of lance gap. The lance outlet is held at a fixed distance above the melt; the bath level is measured continuously, and a winch-driven travelling carriage adjusts the lance height as the level moves. The Generation I carriage lifting speed is about 3 m/min; the Generation II lance extension and retraction speed is 3 m/min. These are travel speeds, not positional tolerances, so the achievable gap stability depends on level measurement, guide stiffness and control deadband.

    Design review should separate static alignment from dynamic correction. Static alignment covers lance verticality, carriage guide clearance and the datum between the lance and furnace mouth. Dynamic correction covers level sensor lag, winch response and the PLC filter that decides when to move. A fast carriage does not compensate for a slow or noisy bath-level signal. Specify the gap band required by the converting recipe, then verify it during cold commissioning at several carriage positions before hot operation.

    Charging practice disturbs the bath that the lance gap control is trying to hold. A Stacked-Type Spent Anode Charging Machine feeds 1.4 t per stack on a 72 s loading cycle; a Plate-Type Anode Scrap Charging Machine feeds up to 84 kg per piece at 200–400 pieces/h. Both change bath level and local temperature between lance corrections. Share the charging sequence with the lance PLC so the carriage does not chase every cold-charge disturbance, and verify the gap band after a full charging cycle rather than only at steady state.

    Maintenance Interval Planning

    A maintenance interval cannot be read from the lance datasheet. Set it from flow deviation at fixed pressure, nozzle wear after each change, and coolant-side trend. The Generation I rotation speed is ≤10 r/min; the Generation II rotation speed is about 8 rpm. Rotation affects wear distribution around the lance, but the interval should still be adjusted from measured nozzle loss rather than from rotation alone. Use the PLC alarm log to link flow excursions with carriage moves and lance changes.

    Plan spares around the wear path, not the whole lance assembly. Keep a complete lance, nozzle inserts and carriage guide consumables staged against the branch layout; eight or fifteen branch positions change the spares ratio. ZXSZ supplies both lance generations under PLC control, which allows a common control philosophy across the converter aisle. Before purchase, issue a data sheet that fixes oxygen range, pressure band, flow per lance and the permissible lance gap band, then require cold-commissioning records for each branch.